Home / Opportunities / Opportunity
PROCUREMENT OPPORTUNITY

Atmospheric gas analyser

University Of Edinburgh · award, contract

Tender information last checkedLast checked 3 Oct 2026, 06:56.

Opportunity overview

SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).

Awarded to

Amounts belong to published awards or contracts. Where several suppliers share one value, it is labelled as shared and is not a supplier-specific allocation.

Contract value
€84.4k
Awarded
Not supplied
Contract signed
12 Mar 2026
Award ID
030291-2026-1
Status
active
Location
Balen, BE213, 2490, Belgium

Classification

  • CPV38344000 — Pollution-monitoring devices

Lots

  • SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).Value not stated

Published notice details

Additional information from the published procurement release. Fields appear only when supplied by the source; check the original notice and tender documents before acting.

Scope, procedure and submissions

Id
NCA21386
Status
complete
Main Procurement Category
goods
Procurement Method
limited
Procurement Method Details
Award procedure without prior publication of a call for competition
Why this procedure was chosen
SUMMARY

Legal basis

Id
32014L0024
Scheme
CELEX

Classification

Scheme
CPV
Id
38344000
Description
Pollution-monitoring devices

Covered By

GPA

Procedure reasons

Entry 1
Scheme
TED_PT_AWARD_CONTRACT_WITHOUT_CALL
Id
D_TECHNICAL
Description
The works, supplies or services can be provided only by a particular economic operator due to absence of competition for technical reasons

Lots and requirements

Entry 1
Id
1
Description
SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).
Has Options
Yes
Status
cancelled

Award criteria

Criteria

Criterion 1
Name
Capability fo fulfil requirement
Type
quality
Description
50
Criterion 2
Name
Cost within budget
Type
cost
Description
50

Options

Description
We may source maintenance services, spare parts and upgrades for the analyser from the awarded supplier.

Items and delivery

Item 1
Id
1
Related Lot
1

Delivery locations

Entry 1
Region
UKM75

Buyer, suppliers and contacts

Organisation 1
Name
University Of Edinburgh
Id
GB-FTS-2023

Identifier

Legal Name
University Of Edinburgh

Address

Street Address
Charles Stewart House, 9-16 Chambers Street
Locality
Edinburgh
Region
UKM75
Postal Code
EH1 1HT
Country Name
United Kingdom

Contact

Telephone
+44 1316502759

Roles

buyer
centralPurchasingBody

Details

Classifications

Entry 1
Scheme
TED_CA_TYPE
Id
BODY_PUBLIC
Description
Body governed by public law
Entry 2
Scheme
COFOG
Id
09
Description
Education
Organisation 2
Name
GeoGas Analytica
Id
GB-FTS-173268

Identifier

Legal Name
GeoGas Analytica

Address

Street Address
Kneveloord 3
Locality
Balen
Region
BE213
Postal Code
2490
Country Name
Belgium

Roles

supplier

Details

Scale
sme
Organisation 3
Name
Edinburgh Sheriff Court
Id
GB-FTS-1033

Identifier

Legal Name
Edinburgh Sheriff Court

Address

Locality
Edinburgh
Country Name
United Kingdom

Roles

reviewBody

Award information

Award 1
Id
030291-2026-1
Status
active

Related lots

1

Suppliers

Supplier 1
Id
GB-FTS-173268
Name
GeoGas Analytica

Contracts and changes

Entry 1
Id
030291-2026-1
Award ID
030291-2026-1
Status
active
Date Signed
12 Mar 2026, 00:00

Value

Amount
84,390
Currency
EUR

Recorded locations

  • Buyer location · Edinburgh · UKM75 · EH1 1HT · United Kingdom
  • Delivery location · UKM75

Notice and amendment history

2 published notice versions reviewed by ProcuraAxis.

2 VERSIONS
  1. 010243-2026award, contract ·
  2. 030291-2026award, contract ·